Content provided by Bryan Orr. All podcast content including episodes, graphics, and podcast descriptions are uploaded and provided directly by Bryan Orr or their podcast platform partner. If you believe someone is using your copyrighted work without your permission, you can follow the process outlined here https://player.fm/legal.
Player FM - Podcast App
Go offline with the Player FM app!

How to Use a Combustion Analyzer w/ Jim Bergmann

59:10
 
Share
 

Manage episode 244155898 series 1264891
Content provided by Bryan Orr. All podcast content including episodes, graphics, and podcast descriptions are uploaded and provided directly by Bryan Orr or their podcast platform partner. If you believe someone is using your copyrighted work without your permission, you can follow the process outlined here https://player.fm/legal.

In this podcast, Jim explains how to use a combustion analyzer. He also talks through the process of combustion analysis using Accutools BluFlame.

The beauty of BluFlame is that it can do CAZ testing, help you set the inches of water column in your furnace, and measure static pressure drop. BluFlame is a tool you can use year-round, not just when you need to measure stack gas.

To learn how to use a combustion analyzer on a typical gas furnace, you have to understand why you're doing it. Combustion analysis is necessary to monitor the health of a furnace system; it's like a doctor measuring your blood pressure at each appointment. You must test for carbon monoxide to protect the homeowners from a potentially deadly situation; combustion analysis can save lives.

First, we have to test for ambient CO, which can be high in cities with lots of cars and air pollution. Then, we start deploying our tools and set them up to check our pressures. After that, we can start the furnace up to collect our readings all at once, which is easy with MeasureQuick. From there, we can use the readings to help us adjust the input settings. After that, we put our analyzer in the stack about 12-16 inches away from the draft inducer motor.

Jim and Bryan also discuss:

  • Jim's involvement in BluFlame
  • Testo probes that do and don't work with BluFlame
  • Clocking the meter and checking input
  • Manometer locations
  • Drilling and sealing holes for testing
  • CO air-free and excess air dilution
  • Overexposing the analyzer to CO
  • Oxygen (O2) content
  • Vacuum in gas furnaces
  • Draft direction
  • Running gas furnaces with other gas appliances (stoves, fireplaces, pool heaters, etc.)
  • Electronic gas leak detectors
  • BluFlame on 80+ vs 90+ furnaces
  • Other gas appliances that require testing

Learn more about Refrigeration Technologies HERE.

If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.
  continue reading

682 episodes

Artwork
iconShare
 
Manage episode 244155898 series 1264891
Content provided by Bryan Orr. All podcast content including episodes, graphics, and podcast descriptions are uploaded and provided directly by Bryan Orr or their podcast platform partner. If you believe someone is using your copyrighted work without your permission, you can follow the process outlined here https://player.fm/legal.

In this podcast, Jim explains how to use a combustion analyzer. He also talks through the process of combustion analysis using Accutools BluFlame.

The beauty of BluFlame is that it can do CAZ testing, help you set the inches of water column in your furnace, and measure static pressure drop. BluFlame is a tool you can use year-round, not just when you need to measure stack gas.

To learn how to use a combustion analyzer on a typical gas furnace, you have to understand why you're doing it. Combustion analysis is necessary to monitor the health of a furnace system; it's like a doctor measuring your blood pressure at each appointment. You must test for carbon monoxide to protect the homeowners from a potentially deadly situation; combustion analysis can save lives.

First, we have to test for ambient CO, which can be high in cities with lots of cars and air pollution. Then, we start deploying our tools and set them up to check our pressures. After that, we can start the furnace up to collect our readings all at once, which is easy with MeasureQuick. From there, we can use the readings to help us adjust the input settings. After that, we put our analyzer in the stack about 12-16 inches away from the draft inducer motor.

Jim and Bryan also discuss:

  • Jim's involvement in BluFlame
  • Testo probes that do and don't work with BluFlame
  • Clocking the meter and checking input
  • Manometer locations
  • Drilling and sealing holes for testing
  • CO air-free and excess air dilution
  • Overexposing the analyzer to CO
  • Oxygen (O2) content
  • Vacuum in gas furnaces
  • Draft direction
  • Running gas furnaces with other gas appliances (stoves, fireplaces, pool heaters, etc.)
  • Electronic gas leak detectors
  • BluFlame on 80+ vs 90+ furnaces
  • Other gas appliances that require testing

Learn more about Refrigeration Technologies HERE.